· Please read all the instructions and follow them carefully!
· Do not use Octanateafter expiry date given on the label.
· During the procedure described below, sterility must be maintained!
· Reconstituted medicinal product should be inspected visually for particulate matter and discoloration prior to administration. The solution should be clear or slightly opalescent. Do not use solutions that are cloudy or have deposits. Use the prepared solution immediately, to prevent microbial contamination.
·Only use the injection set provided. The use of other injection/infusion equipment can cause additional risks and treatment failure.
Instructions for preparing the solution:
1. Do not use the product directly from the refrigerator. Allow the solvent and the powder in the closed vials to reach room temperature.
2. Remove the flip off caps from both vials and clean the rubber stoppers with one of the provided alcohol swabs.
3. The Mix2vial™ is depicted in Fig. 1. Place the solvent vial on an even surface and hold it firmly. Take the Mix2Vial™ and turn it upside down. Place the blue part of the Mix2Vial™ on top of the solvent vial and press firmly down until it snaps (Fig. 2+3).



Instructions for injection:
As a precaution, your pulse rate should be taken before and during the injection. If a marked increase in your pulse rate occurs, reduce the injection speed or interrupt the administration for a short time.
1. Attach the syringe to the transparent part of the Mix2Vial™. Turn the vial upside down and draw the solution into the syringe (Fig. 6).
The solution in the syringe should be clear or slightly pearly shimmery.
Once the solution has been transferred, firmly hold the plunger of the syringe (keeping it facing down) and
remove the syringe from the Mix2Vial™ (Fig. 7). Dispose the Mix2Vial™ and the empty vial.

2. Clean the chosen injection site with one of the provided alcohol swabs.
3. Attach the provided injection set to the syringe
4. Insert the injection needle into the chosen vein. If you have used a tourniquet to make the vein easier to see, this tourniquet should be released before you start injecting Octanate.
No blood must flow into the syringe due to the risk of formation of fibrin clots.
5. Inject the solution into the vein at a slow speed, not faster than 2-3 ml per minute.
If you use more than one vial of Octanate powder for one treatment, you may use the same injection set and syringe again. The Mix2Vial™ is for single use only.
Any unused medicinal product or waste material should be disposed of in accordance with local requirements.